Serial Data Port

serial-data.gif

PIN

RS232

1

DCD

2

RxD

3

TxD

4

DTR

5

GND

6

DSR

7

RTS

8

CTS

 

Parameters:

Baud rate: 115200

Flow Control: None

Parity: None

Data Bite: 8

Stop Bit: 1

 

Example of string format for sending ASCII data to I-Mark Placeholder:

 

Single Placeholder

 

[ : ]   "DATA TO BE MARKED”   [CRLF]

 

Start of string = [ : ]

Data to be printed by marking head =   ”DATA TO BE MARKED”

End of String = [CRLF]

 

Multiple Placeholders (up to 10 may be used)

 

[ : ]   ”DATA TO BE MARKED”   [CRLF]

[ : ]   ”DATA TO BE MARKED”   [CRLF]

[ : ]   ”DATA TO BE MARKED”   [CRLF]

[ : ]   ”DATA TO BE MARKED”   [CRLF]

[ : ]   ”DATA TO BE MARKED”   [CRLF]

[ : ]   ”DATA TO BE MARKED”   [CRLF]

[ : ]   ”DATA TO BE MARKED”   [CRLF]

[ : ]   ”DATA TO BE MARKED”   [CRLF]

[ : ]   ”DATA TO BE MARKED”   [CRLF]

[ : ]   ”DATA TO BE MARKED”   [CRLF]

 

Data to be marked may be filled with "NULL" for a non-printed placeholder.